Abstract

The relative occlusal force and real-time occlusal contact timing data provided by the T-Scan technology can be used to manage the insertion occlusal force design of implant prostheses, as their long-term survivability is tied directly to their installed occlusal function. This chapter discusses how in daily dental practice clinicians spend a great deal of time making corrective occlusal adjustments using solely articulating paper as their intended guide. However, current research shows that articulating paper markings do not measure occlusal force, such that implant occlusal force control is compromised, which can lead to peri-implant tissue loss, breakage of implant restorative components, and de-osseointegration. However, by using the T-Scan technology, the clinician eliminates the subjectivity involved in using articulating paper ensuring the occlusal design of newly installed implant prostheses are optimal improving prosthesis longevity. Examples are presented of how T-Scan force and time data can aid in implant restoration occlusal force control.
Chapter Preview
Top

Introduction

Although implant 5-year survival rates are reported to be 90% - 95% (Koldsland, Scheie, & Aass, 2009; Astrand, Ahlqvist, Gunne, Nilson, 2008; Nixon, Chen, & Ivanovski, 2009), it has been shown that prosthesis occlusal material damage, and superstructure breakage, can compromise the longevity of an implant supported prosthesis. In one published study involving 76 implant restorations, reported that within 3.25 years of intraoral service, 70% (n = 56) of the delivered implant prostheses sustained documented dental material damage or breakage (Kaptein, DePutter, Delange, & Blijdorp, 1999). These poor material longevity results are due to both the lack of the Periodontal Ligament “cushioning effect” that is absent with dental implants, and from “articulating paper or foil-only” delivery occlusal adjustments, that are made during the insertion of these rigid prostheses, as they sit upon the osseous integrated implant. Because of the lack of shock absorbency within the bone surrounding dental implants, potentially damaging occlusal forces rise very quickly on an implant prosthesis’ occlusal surface. Also, the proper locations of any occlusal force excess will not be quantifiably and reliably described to the clinician by the shape and size of articulating paper markings (Gazit, Fitzig, & Lieberman, 1986; Carossa, Lojacono, Schierano, & Pera, 2000; Millstein & Maya, 2001; Carey, Craig, Kerstein, & Radke, 2007; Saad, Weiner, & Ehrenberg, 2008; Qadeer, et. al., 2012). There is no predictable occlusal force control on implant prostheses when insertion occlusal adjustments are performed without measuring occlusal contact time and force. Therefore, the regions of excess occlusal forces are often not removed during the insertion occlusal adjustment procedures, which can lead to the rapid occlusal surface dental material breakdown clinically observed and reported (Kaptein, DePutter, Delange, & Blijdorp, 1999).

Dental implants have been shown to depress vertically within the alveolar bone approximately one fifth of amount that a natural tooth depresses. In addition, horizontally, implants demonstrate less than 50% of the lateral movement that a natural tooth can undergo (Sekine et al., 1986). Moreover, teeth adjacent to an implant when loaded, provide proprioception from the Periodontal Ligament that impacts muscle activity level control over normal chewing function. Implants have none of this proprioceptive feedback, such that the initial contact of the teeth adjacent to an implant, engages the protective proprioception of the adjacent teeth, which is critical for preventing early contact and occlusal force overload from being placed upon the implant.

This implant-tooth movement discrepancy can be compensated for by employing the T-Scan system’s (Tekscan Inc. S. Boston, MA, USA) ‘Time-delay’ principle (Kerstein, 2002), which creates a purposeful late loading of an implant prosthesis that occurs after teeth have begun to sink into their Periodontal Ligaments. In this way, the amount of damaging occlusal forces placed upon the implant prosthesis is lessened. Employing a Time-delay in the occlusion can protect the implant components, the prosthesis superstructure, and the peri-implant soft tissue and supportive bone (Kerstein, 2002).

A full mouth implant prosthesis does not have the same movement discrepancy present when implants and teeth reside in the same arch. Therefore, the occlusal design of a full mouth implant prosthesis differs from the that of combined implant and natural teeth prosthesis. Hobo suggested that when making a fully implant supported prosthesis, one should employ a mutually protected occlusion to obtain posterior disclusion in eccentric movements (Hobo, Ichida, & Garcia, 1989). However, the conventional way to establish posterior disclusion using visual inspection is not quantitative. More importantly, posterior disclusion itself cannot solve all the occlusal problems that can arise in a full mouth implant prosthesis.

Key Terms in this Chapter

Tooth Time Software Analysis: A T-Scan III software feature that compares the force loading of one specific tooth, to the time of force loading of all of the other teeth.

Time-Delay: In mixed implant-natural tooth occlusion, the occlusal scheme applies sequential force to the natural teeth before the implants initially occlude.

Full Mouth Implant Reconstruction: A complete mouth implant supported rehabilitation performed on a fully edentulous patient.

Electromyography (EMG): A computer technology that records and measures the contractile activity of masticatory muscle function.

T-Scan III System: A computer technology that records, and measures the timing of occlusal contacts and the relative forces of the occlusion.

Disclusion Time Reduction: The act of minimizing prolonged occlusal surface friction on posterior teeth or posterior implant prostheses, to be < 0.4 seconds per excursion, by performing the Immediate Complete Anterior Guidance Development (ICAGD) coronoplasty procedure.

Implant Occlusion: The implant occlusal scheme considers that the movement features of a dental implant are different than those of a tooth.